Tillbaka till svenska Fidonet
English   Information   Debug  
ENET.SOFT   0/11701
ENET.SYSOP   33903
ENET.TALKS   0/32
ENGLISH_TUTOR   0/2000
EVOLUTION   0/1335
FDECHO   0/217
FDN_ANNOUNCE   0/7068
FIDONEWS   24126
FIDONEWS_OLD1   0/49742
FIDONEWS_OLD2   0/35949
FIDONEWS_OLD3   0/30874
FIDONEWS_OLD4   0/37224
FIDO_SYSOP   12852
FIDO_UTIL   0/180
FILEFIND   0/209
FILEGATE   0/212
FILM   0/18
FNEWS_PUBLISH   4408
FN_SYSOP   41678
FN_SYSOP_OLD1   71952
FTP_FIDO   0/2
FTSC_PUBLIC   0/13599
FUNNY   0/4886
GENEALOGY.EUR   0/71
GET_INFO   105
GOLDED   0/408
HAM   0/16070
HOLYSMOKE   0/6791
HOT_SITES   0/1
HTMLEDIT   0/71
HUB203   466
HUB_100   264
HUB_400   39
HUMOR   0/29
IC   0/2851
INTERNET   0/424
INTERUSER   0/3
IP_CONNECT   719
JAMNNTPD   0/233
JAMTLAND   0/47
KATTY_KORNER   0/41
LAN   0/16
LINUX-USER   0/19
LINUXHELP   0/1155
LINUX   0/22092
LINUX_BBS   0/957
mail   18.68
mail_fore_ok   249
MENSA   0/341
MODERATOR   0/102
MONTE   0/992
MOSCOW_OKLAHOMA   0/1245
MUFFIN   0/783
MUSIC   0/321
N203_STAT   926
N203_SYSCHAT   313
NET203   321
NET204   69
NET_DEV   0/10
NORD.ADMIN   0/101
NORD.CHAT   0/2572
NORD.FIDONET   189
NORD.HARDWARE   0/28
NORD.KULTUR   0/114
NORD.PROG   0/32
NORD.SOFTWARE   0/88
NORD.TEKNIK   0/58
NORD   0/453
OCCULT_CHAT   0/93
OS2BBS   0/787
OS2DOSBBS   0/580
OS2HW   0/42
OS2INET   0/37
OS2LAN   0/134
OS2PROG   0/36
OS2REXX   0/113
OS2USER-L   207
OS2   0/4786
OSDEBATE   0/18996
PASCAL   0/490
PERL   0/457
PHP   0/45
POINTS   0/405
POLITICS   0/29554
POL_INC   0/14731
PSION   103
R20_ADMIN   1121
R20_AMATORRADIO   0/2
R20_BEST_OF_FIDONET   13
R20_CHAT   0/893
R20_DEPP   0/3
R20_DEV   399
R20_ECHO2   1379
R20_ECHOPRES   0/35
R20_ESTAT   0/719
R20_FIDONETPROG...
...RAM.MYPOINT
  0/2
R20_FIDONETPROGRAM   0/22
R20_FIDONET   0/248
R20_FILEFIND   0/24
R20_FILEFOUND   0/22
R20_HIFI   0/3
R20_INFO2   3218
R20_INTERNET   0/12940
R20_INTRESSE   0/60
R20_INTR_KOM   0/99
R20_KANDIDAT.CHAT   42
R20_KANDIDAT   28
R20_KOM_DEV   112
R20_KONTROLL   0/13271
R20_KORSET   0/18
R20_LOKALTRAFIK   0/24
R20_MODERATOR   0/1852
R20_NC   76
R20_NET200   245
R20_NETWORK.OTH...
...ERNETS
  0/13
R20_OPERATIVSYS...
...TEM.LINUX
  0/44
R20_PROGRAMVAROR   0/1
R20_REC2NEC   534
R20_SFOSM   0/340
R20_SF   0/108
R20_SPRAK.ENGLISH   0/1
R20_SQUISH   107
R20_TEST   2
R20_WORST_OF_FIDONET   12
RAR   0/9
RA_MULTI   106
RA_UTIL   0/162
REGCON.EUR   0/2056
REGCON   0/13
SCIENCE   0/1206
SF   0/239
SHAREWARE_SUPPORT   0/5146
SHAREWRE   0/14
SIMPSONS   0/169
STATS_OLD1   0/2539.065
STATS_OLD2   0/2530
STATS_OLD3   0/2395.095
STATS_OLD4   0/1692.25
SURVIVOR   0/495
SYSOPS_CORNER   0/3
SYSOP   0/84
TAGLINES   0/112
TEAMOS2   0/4530
TECH   0/2617
TEST.444   0/105
TRAPDOOR   0/19
TREK   0/755
TUB   0/290
UFO   0/40
UNIX   0/1316
USA_EURLINK   0/102
USR_MODEMS   0/1
VATICAN   0/2740
VIETNAM_VETS   0/14
VIRUS   0/378
VIRUS_INFO   0/201
VISUAL_BASIC   0/473
WHITEHOUSE   0/5187
WIN2000   0/101
WIN32   0/30
WIN95   0/4288
WIN95_OLD1   0/70272
WINDOWS   0/1517
WWB_SYSOP   0/419
WWB_TECH   0/810
ZCC-PUBLIC   0/1
ZEC   4

 
4DOS   0/134
ABORTION   0/7
ALASKA_CHAT   0/506
ALLFIX_FILE   0/1313
ALLFIX_FILE_OLD1   0/7997
ALT_DOS   0/152
AMATEUR_RADIO   0/1039
AMIGASALE   0/14
AMIGA   0/331
AMIGA_INT   0/1
AMIGA_PROG   0/20
AMIGA_SYSOP   0/26
ANIME   0/15
ARGUS   0/924
ASCII_ART   0/340
ASIAN_LINK   0/651
ASTRONOMY   0/417
AUDIO   0/92
AUTOMOBILE_RACING   0/105
BABYLON5   0/17862
BAG   135
BATPOWER   0/361
BBBS.ENGLISH   0/382
BBSLAW   0/109
BBS_ADS   0/5290
BBS_INTERNET   0/507
BIBLE   0/3563
BINKD   0/1119
BINKLEY   0/215
BLUEWAVE   0/2173
CABLE_MODEMS   0/25
CBM   0/46
CDRECORD   0/66
CDROM   0/20
CLASSIC_COMPUTER   0/378
COMICS   0/15
CONSPRCY   0/899
COOKING   32896
COOKING_OLD1   0/24719
COOKING_OLD2   0/40862
COOKING_OLD3   0/37489
COOKING_OLD4   0/35496
COOKING_OLD5   9370
C_ECHO   0/189
C_PLUSPLUS   0/31
DIRTY_DOZEN   0/201
DOORGAMES   0/2056
DOS_INTERNET   0/196
duplikat   6002
ECHOLIST   0/18295
EC_SUPPORT   0/318
ELECTRONICS   0/359
ELEKTRONIK.GER   1534
ENET.LINGUISTIC   0/13
ENET.POLITICS   0/4
Möte FIDONEWS_OLD3, 30874 texter
 lista första sista föregående nästa
Text 9990, 114 rader
Skriven 2010-08-17 22:13:56 av Michiel van der Vlist (2:280/5555)
     Kommentar till en text av Robert Bashe (2:2448/44)
Ärende: Just Curious
====================
Hello Robert,

On Tuesday August 17 2010 18:21, you wrote to me:

 MV>> But what is stopping an idiot from replacing a 16A breaker with a
 MV>> 50A one if it keeps triggering?

 RB> Availability would be my answer - I'm not even sure if they make
 RB> breakers in the particular form you need with higher ratings than 16A.

Sure they do, no problem. These dircuit breakers are pretty standarad and
available up to 63A in the same housing.

http://tinyurl.com/27ywxzu


And if you can not find one... what is stopping an idiot from bridging it with
a piece of wire?

 RB> And of couse, that would be more work than shorting a fuse. Have to
 RB> think of the laziness of people ;-)

Not if they are of the new "just insert, no screws type"...

 RB>>> Our main line fuses can be replaced by the customer -

 MV>> How does the power company stop people from stealing electricity
 MV>> if they can simple tap in before the meter by removing the main
 MV>> fuses and plugging in something else?

 RB> The fuses are _after_ the meter, not before.

Ah, I see.

 RB> No way you can get at the lines going into the meter unless you
 RB> actually work with the live wires - and something like that would be
 RB> evident the next time the meter is read or the electricity company
 RB> wanted to check anything.

I would not be too sure of that. Things like that HAVE been done you know.

Here the main fuses are befort the meter.

http://www.vlist.eu/fotos/electra-5.jpg  On the lower left, you see he gray
cable that runn to the streat. It terminates in the black box with the red card
with the emergency number from the power company. In that box is the main 35A
fuse. There is room for two more fuses to expand to a three phase installation.
That box is sealed. You can just see the seal at the lower left corner of the
box.

Above it is the meter, also sealed. The box on top of the meter is the main
switch. In this picture temporarely connected to a 32A CEEform socket. In that
plugs a temporary fuse box with two 16A fuses. Thet is the orange box right of
the big grey box that is the invertor fot the solar cels.

This isn't really a legal way of making a temporary connection, but I figured
it was safe enough as a temporary setup while I renewed the installation.

See the whole article at http://www.vlist.eu/electra/

In the last picture (click to enlarge) you can see the end result. At the top
there are seven circuits with fuses and switches. Above the manin switch is the
box with the earth differential switches. Above the inverter are the Volt and
Amp meter for the solar cells. The Ferraris meter n the right measure totak
power generated by the solar cells.

 RB>>> We also have what they call FI switches here, which trip and
 RB>>> interrupt the power when a certain small amperage (I believe
 RB>>> 50-100 mA) drains to ground...

Ah, "Fehler Interuptor"

 MV>> Those are a circuit breaker and an earth differential switch in
 MV>> one package. They trip at 16 A overload or 30 mA differential.
 MV>> Here they are called "alamat".

 RB> The two are separate here.

Same as in my house then.

 RB> There are circuit breakers for the various circuits in the house, and
 RB> a line of FI switches at the top of the electric cabinet for the
 RB> various circuits in the house.

So each circuit has its own FI switch? There s a difference. Here on may run a
maximum ov four circuits on one FI switch.That is why the FI switches are
before tha circuit breakers.

 RB> I might add that 30 mA seems a little low to me. I think we have 50 mA
 RB> here,

Doubt it. 30 mA is a EU standard. Heve a close look at the thing, the rating
wil be on it. In small print....

 RB>  and in agriculture (stalls, barns) they use 100 mA. If the FI
 RB> switch has an excessively low rating, it will trip at the slightest
 RB> problem again and again, cutting off your power.

The 30 mA is for residential buildings. Higher values are allowd in an
industrial environment.

 RB> I had that problem when I first moved into my renovated (and
 RB> professionally re-wired) house, finally only could eliminate it by
 RB> increasing the rating slightly, and since then no problems - also no
 RB> electrical shocks. This kind of thing can be overdone.

There exists a 10 mA variety. Maybe you had one of those. One can indeed overdo
things.


Cheers, Michiel

--- GoldED+/W32-MINGW 1.1.5-b20070503
 * Origin: http://www.vlist.org (2:280/5555)